Basic Info.
Application
High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Principle of Work
V/F Control Transducer
Voltage of Power Supply
High Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Simple Type, Elevator Special, Textile Special, Constant Torque Universal Type
Product Description
Z2000 Series Compact Vector Control ·Senseless flux vector control (VC) V/F (Voltage/Frequency) Control · Overload capacity is 60s for 150% of the rated current, 3s for 180% of the rated current. · There are ten auxiliary frequency sources. · It can implement fine tuning of auxiliary frequency and frequency synthesis ·Support PM motor (Z2000 T series) · Power range: 220V 0.4~7.5kW 380V 0.75~450kW |
Item | Z2000 |
Standard function | Control mode | Senseless flux vector control(SFVC) Voltage/Frequency (V/F) control |
Maximum frequency | Vector control: 0-320Hz V/F control: 0-3200Hz |
Carrier frequency | 1-16kHz The carrier frequency is automatically adjusted based on the load features |
Input frequency solution | Digital setting: 0.01Hz Analog setting: maximum frequency x 0.025% |
Startup torque | G type: 0.5Hz/150%(SFVC) P type: 0.5Hz/100% |
Speed range | 1:100 |
Speed stability accuracy | ±0.5% |
Overload capacity | G type: 60s for 150% of the rated current, 3s for 180% of the rated current. P type: 60s for 120% of the rated current, 3s for 150% of the rated current |
Torque boost | Auto boost; Customized boost 0.1%-30.0% |
V/F curve | Line V/F curve; Multi-point V/F curve; N-power V/F curve |
V/F separation | Two types: complete separation; half separation |
Ramp mode | Straight-line ramp; S-curve ramp; Four groups of acceleration/deceleration time with the range of 0.0-6500.0s |
DC braking | DC braking frequency: 0.0Hz to maximum frequency Braking time: 0.0~100.0s Braking action current value: 0.0%~100.0% |
JOG control | JOG frequency range: 0.00~50.00Hz JOG acceleration/deceleration time: 0.0~6500.0s |
Onboard multiple preset speeds | It implements up to 16 speeds via the simple PLC function or combination of X terminal states. |
Onboard PID | It realizes process-controlled closed loop control system easily |
Auto voltage regulation (AVR) | It can keep constant output voltage automatically when the mains voltage changes. |
Auto voltage/ Over current stall control | The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage / over current |
Rapid current limit | It helps to avoid frequent over current faults of the AC drive |
Torque limit and control | It can keep constant output voltage automatically when the mains voltage changes |
Address:
Shanghai Wealth Building, Zhenhai District, Ningbo
Business Type:
Trading Company
Business Range:
Electrical & Electronics
Company Introduction:
Our company offers variety of products which can meet your multifarious demands. We adhere to the management principles of "quality first, customer first and credit-based" since the establishment of the company and always do our best to satisfy potential needs of our customers. Our company is sincerely willing to cooperate with enterprises from all over the world in order to realize a win-win situation since the trend of economic globalization has developed with anirresistible force.