TYPE | SPECIFICATIONS |
220V | Horsepower capacity(HP) | 0.5 | 1 | 2 | 3 | 5 | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 | | | | | | | | | | | | |
Rated power(KW) | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | | | | | | | | | | | | |
Rated capacity(KVA) | 1.5 | 3.0 | 4.0 | 5.9 | 8.9 | 17 | 21 | 30 | 40 | 57 | 69 | 85 | 114 | 134 | 160 | 231 | | | | | | | | | | | | |
Rated current(A) | 2.1 | 3.8 | 5.1 | 9.0 | 18 | 25 | 32 | 45 | 60 | 75 | 91 | 112 | 150 | 176 | 210 | 304 | | | | | | | | | | | | |
380 | Horsepower capacity(HP) | | 1 | 2 | 3 | 5 | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 | 120 | 150 | 180 | 200 | 270 | 300 | 340 | 380 | 428 | 482 | 545 | 612 |
Rated power(KW) | | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 | 160 | 200 | 220 | 250 | 280 | 315 | 355 | 400 | 450 |
Rated capacity(KVA) | | 1.5 | 3.0 | 4.0 | 5.9 | 8.9 | 11 | 17 | 21 | 24 | 30 | 40 | 57 | 69 | 85 | 114 | 134 | 160 | 192 | 231 | 250 | 280 | 355 | 396 | 445 | 565 | 629 | 714 |
Rated current(A) | | 2.1 | 3.8 | 5.1 | 9.0 | 13 | 17 | 25 | 32 | 37 | 45 | 60 | 75 | 91 | 112 | 150 | 176 | 210 | 253 | 304 | 377 | 426 | 465 | 520 | 585 | 650 | 725 | 820 |
Personalized function | The highest frequency | V/F control: 0~500Hz ,vector control:0~500Hz |
Carrier frequency | 0.5kHz~16kHz ;according to the load characteristics, can be adjusted carrier frequency automatically. |
The input frequency resolution | Digital setting:0.01Hz ;simulation setting: the highest frequency *0.025% |
Control mode | Open loop vector control(SVC), V/F control |
Starting torque | 0.5Hz/1 50%(SVC) |
Speed range | 1:100(SVC) |
The steady speed precision | +/-0.5%(SVC) |
Overload capacity | 150%rated current 60s; I 80%rated current 3s; |
Torque boost | Automatic torque boost: manual torque boost0. 1%~30.0% |
V/F curve | In three ways: straight, multi-point type, square type; . |
Acceleration and deccleration curve | linear or S curve acceleration and deceleration mode: four kinds of acceleration and deceleration time; acceleration and deceleration time range0.0~6500.0s |
DC brake | DC braking frequency: 0.00Hz~the maximum frequency; the braking time:0.0s~36.0s, braking action current value:0.0%~100.0% |
Motor-driven control | Dynamic frequency range:0.00Hz~50.00Hz;motor-driven acceleration and deceleration time:0.0s-6500.0s |
Simple PLC, multi-speed operation | Through the built-in PLC or control terminal to achieve 16 speed at most |
Built-in PID | Can be convenient to realize closed-loop control of process control system) |
Automatic voltage regulator(AVR) | When the power voltage changes,automatically keep the output voltage constant |
Overvoltage and overcurrent stall control | Current and voltage automatically limit during the operation, prevent frequent over-voltage and over-current trip |
Fast current limiting function | Maximum limit reduce overcurrent faults, protect the inverter operation |
Torque limit and control | excavator characteristics, the automatic torque limit during the operation, prevent frequent over-current trip |
Power on peripheral equip ment safely self-inspection | can be realized on the peripheral devices safety inspection, such as grounding, short |
Common DC bus function | can realize multiple inverters of common DC bus function |
Textile swing frequency control | multiple delta frequency control |
Timing control | timing control function: set the time range 0h~65535h |
Run | Run the command channel | three channels:Operation panel given , control terminal given , serial communication port terminals are given. Through a variety of mode switching |
The frequency of the source | total of 10 kinds of frequency source: given digital,analog voltage given , analog current given, pulse given, serial port given. Through a variety of mode switching) |
Auxiliary frequency source | 10 kind of auxiliary frequency source.Flexible to realize the frequency tuning, frequency synthesis |
The input terminal | five digital input, one may make the high speed pulse input, up to a maximum of 100KHz; two analog input terminals, one can only be used as voltage input, another can be used as a voltage or current input |
The output terminal | a high-speed pulse output terminal (optional for open collector type), 0kHz~ 100kHz square wave signal output, can realize output frequency setting, the output frequency and other physical quantity; a digital output terminal; a relay output terminal; an analog output terminals, respectively, the optional 0/4mA~ 20mAhuo 0/2V-10V, the output can be set frequency, the output frequency and other physical quantity |
Environment | The use of occasions | indoor, not direct sunlight, no dust, corrosive gas, flammable gas, oil mist, water vapor, water or salt etc. |
Altitude | below 1000m |
The environment temperature | -10C ~+40C (The environment temperature At 40C ~ 50C ambient temperature, amount to usc) |
Humidity | below95%RH, no beads of condensation |
Vibration | bclow5.9m/s2(0.6g) |
Storage temperature | -20C ~+60C |