Items | NZ100 |
Power Supply | Rated voltage, Frequency | One-phase/Three-phase AC 220V/380V 50/60Hz |
Voltage Range | 220V: 170~240V 380V: 330V~440V |
Output | Voltage Range | 220V: 0~220V 380V: 0~380V |
Frequency Range | 0.10~400.00Hz |
Control method | V/F control |
Indication | Operating status/Alarm definition/interactive guidance: frequency setting, the output frequency/ current, DC bus voltage and so on. |
Control Speculations | Output Frequency Range | 0.10Hz~400.00Hz |
Frequency Setting Resolution | Digital input: 0.10Hz, analog input: 0.1% of maximum output frequency |
Output Frequency Accuracy | 0.01Hz : |
V/F Control | Setting VIF curve to satisfy various load requirements. |
Torque Boost | Auto increase: auto raise torque by loading Condition; Manual increase: enable to set 0.0~20.0% of raising torque. |
Multifunctional Input Terminal | Four multi-function input terminals, realizing functions including eight section speed control, Program running, four-section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions |
Multifunctional Output Terminal | 1 multi-function output terminals for displaying of run, zero speed, external abnormity, program operation and other information and warings. |
Acceleration/ Deceleration Time Setting | 0~999.9s acceleration/deceleration time can be set individually. |
Other functions | PID Control | Built-in PID control |
RS485 | Standard RS485 communication function(MODBUS) |
Frequency Setting | Analog input:0~ 10V, 4~20mA Digital input: Operation panel or RS485 or UP/DOWN. Note: AVI terminals can be used to select an Analog voltage input (AV) and analog current input (AI) through the switch J2. |
Multi-speed | Four multifunction input terminals, 15 section speed can be set |
Automatic Voltage Regulation | Automatic voltage regulation function can be selected |
Counter | Built-in 2 group of counters |
Protection/ Warning Function | Overload | 150%, 60 second(Constant torque) |
Over Voltage | Over voltage protection can be set. |
Under Voltage | Under voltage protection can be set |
Other Protections | Output short circuit, over current, and parameter lock and so on. |
Environment | Ambient Temperature | -10°C to 40°C(non-freezing) |
Ambient Humidity | Max.95% (non-condensing) |
Altitude | Lower than 1000m |
Vibration | Max.0.5G |
Structure | Cooling Mode | Forced air cooling |
Protective Structure | IP 20 |
Installation | Wall-mounted or standard 35mm rail mounting (≤5.5kW) |